Equipped with a sturdy protective case, the Intra model is suitable for surface roughness and profile

Technical Description

  • Measuring range (Z) 1mm/ resolution 16nm. Provides contour measurement as well as surface roughness measurement requiring high accuracy and portability
  • Measuring stroke up to 50mm. Ideal for measuring applications in workshops and construction sites.
  • Straightness 0.4 µm/ 50mm. High precision of the reference axis allows for sliding-type waviness, form and contour measurements even on large samples.
  • The smallest sampling interval of only 0.5 µm is very suitable for measuring and analyzing small samples.
  • Manually adjustable vertical travel accommodates large and tall samples, providing stability and precision like a stationary machine

Specifications

Overview
Horizontal Performance
Traverse length - X Min / Max0.1mm to 50mm (0.004in to 1.97in)
Traverse / measuring speeds10mm/s (0.39in/s) max - 1mm/s (0.039in/s)
Data sampling interval in X0.5 μm (20 μin )
Straightness error (Pt)0.4 μm over 50 mm (16 μin over 1.96 in)
0.2 μm over any 20 mm (8 μin over any 0.78 in)
Vertical Performance
Nominal measuring range (Z)1mm (0.04in )
Resolution (Z)16nm @ 1mm range (0.63 μin @ 0.04 in)
3nm @ 0.2mm range (0.12 μin @ 0.008 in)
Range to resolution ratio65,536 : 1
Stylus arm length, tip size, force60mm arm, 2μm radius conisphere diamond stylus, 1mN force
System Performance
Spherical calibration artifact12.5mm (0.49 in) nominal radius
Calibration uncertainty - Pt< 0.25μm (10 μin)
Radius measurement uncertainty0.1 - 12.5mm (0.004 - 0.5 in) = 2% to 0.04% of nominal
12.5 - 25mm (0.5 - 1in) = 0.04% of nominal
25 - 1000mm (1 - 39.4in) = 0.04% to 0.2% of nominal
Angle measurement uncertaintywithin 1% of measured angle (+ / - 35º maximum range)
Parameter height uncertaintywithin 2% + 6nm (0.24μin) (peak parameters only)
Dimensions L x D x HTraverse unit - 343 x 116 x 160mm (13.5 x 4.6 x 6.3in)
Control module - 285 x 200 x 80mm (11.2 x .9 x 3.2in)
WeightTraverse unit - 4.9Kg (10.8lbs)
Control module - 1.9Kg (4.2lbs)
Environment notes
Storage temperature5ºC to 40ºC (41ºF to 104ºF)
Storage humidity10% to 80% Relative, non condensing
Operating temperature15ºC to 30ºC (59ºF to 86ºF)
Temperature gradient< 2ºC (< 3.6ºF) per hour
Operating humidity45% to 75% Relative, non condensing
Maximum RMS floor vibration2.5 μm/s (100 μin/s) at < 50Hz
5.0 μm/s (200 μin/s) at > 50Hz
Electrical supply110/220/240V - 50/60 Hz
Power consumption10VA traverse unit / 18VA processor
SafetyEN 61010 - 1 : 2001
EMCEN 61000 - 6 - 4 : 2001
EN 61000 - 6 - 1 : 2001
Note: Taylor Hobson pursues a policy of continual improvement due to technical developments. We therefore reserve the right to deviate from catalog specifications.

Related Products

Taylor Hobson - Form Talysurf Intra Touch

Portable Roughness Measuring & Analyzing Equipment

Taylor Hobson - Form Talysurf Intra Touch

Taylor Hobson - Surtronic S-100 Series

Handheld roughness meter with spectrum display

Taylor Hobson - Surtronic S-100 Series

Taylor Hobson - Surtronic Duo

Simple handheld roughness measuring device

Taylor Hobson - Surtronic Duo

Are you interested in our products?
Need a quote for a product or equipment?

Please contact our team of experts for free and professional advice