Roundness, Roughness, and Contour Analyzer
Taylor Hobson - Talyrond 595H Range
Equipped with ultra-precision stepper motors on all operating axes and an active anti-vibration mount, the Talyrond 595H...
Gọi (+84) 828 31 08 99 để được tư vấn.
Technical Description
- Application to measure roundness parameters of mechanical parts such as bearings, cylinders, crankshafts, computer hard drives, fuel injectors, lathe or grinding parts...
- Measures roundness parameters such as: roundness, parallelism, cylindricality, straightness, flatness, coaxiality, concentricity, eccentricity, radial runout, perpendicularity, discontinuous measurement, analysis of uneven planes, thickness variation
- The rotating disc has the ability to automatically center and level flat.
- Specially designed and precision lever arm with automatic vertical/horizontal rotation and angle setting (Talyrond 585/ 595)
- Column height: 300mm/ 500mm/ 900mm
- Sample diameter: max Ø400mm (can be up to Ø485mm); Measuring diameter: max Ø350mm
- Air bearing rotating shaft operates frictionlessly, high precision
- The stand is equipped with an active anti-vibration system with very high sensitivity (Talyrond 595)
- The column and base are designed to be sturdy, ensuring that the operating system is not affected by the mass and displacement of the specimen.
- Ultra software is simple to use, giving fast and accurate results.
Specifications
Measurement capability | ||
Column axis | 300 mm column | 500 mm column |
Straightness over column length | 0.2 µm / 300 mm (8 µin / 11.8 in) | 0.2 µm / 500 mm (8 µin / 19.7 in) |
Straightness over any 100mm (3.94in) | 0.12 µm / 100 mm (4.7 µin / 3.94 in) | 0.15 µm / 100 mm (5.9 µin / 3.94 in) |
Vertical axis to spindle axis parallelism | 0.5 µm / 300 mm (20 µin / 11.8 in) | 0.5 µm / 500 mm (20 µin / 19.7 in) |
Length measurement | (0.03 µm/mm + 1.5 µm) | |
Column noise † | <2 0 nm Rq | |
Spindle axis | ||
Radial limit of error | ± 0.008 µm (1-15 upr) or ± 0.01 µm (1-50 upr) | |
Axial limit of error | ± 0.01 µm (1-15 upr) or ± 0.015 µm (1-50 upr) | |
Coning Error (height above table) | ± 0.00025 µm/mm | |
Coning Error (radius from centre) | ± 0.00025 µm/mm | |
Horizontal arm axis | Radial straightness unit | |
Straightness over full length of travel | 0.2 µm / 200 mm (4 µin / 7.9 in) | |
Straightness over any length of travel | 0.125 µm + 0.000375 µm/mm (5 µin + 0.015 µin/in) | |
Squareness to spindle axis | 1 µm / 200 mm (39.4 µin / 7.9 in) | |
Radial measurement * | (0.1 µm/mm + 1.5 µm) | |
Arm noise † | <20 nm Rq | |
Gauge | Range/resolution | |
High range | ± 2 mm , 0.016 µm resolution (0.078 in range, 0.6 µin resolution) | |
Normal range | +/- 1 mm range, 0.008 µm resolution (0.039 in range, 0.3 µin resolution) | |
Mid range | +/- 0.2 mm range, 0.0016 µm resolution (0.0078 in range, 0.06 µin resolution) | |
Low range | +/- 0.04 mm range, 0.0003 µm resolution (0.003 in range, 0.012 µin resolution) | |
Component capacity | ||
Measuring capacity | 300 mm column | 500 mm column |
Maximum component height | 300 mm (11.82 in) | 500 mm (19.7 in) |
Maximum component diameter | Ø 400 mm (15.7 in) | |
Maximum measuring depth | 155 mm (6.1 in) | |
Maximum measuring diameter | Ø 350 mm (13.8 in) | |
Maximum component weight | Auto Center and Level: 40 kg (88 lb) | |
Maximum worktable moment loading | Auto C&L: 1250 kg/mm (108 lb/in) within a central 80 mm (3.15 in) equilateral triangle | |
Technical | ||
Column axis | 300 mm column | 500 mm column |
Column construction | Precision machined cast iron datum | |
Movement range | 300 mm (11.8 in) | 500 mm (19.7 in) |
Speed of traverse | moving: 0.1 - 105 mm/s (0.04 - 4.1 in/s) stepped | |
measuring: 0.1 - 20 mm/s (0.01 - 0.8 in/s) stepped | ||
contacting: 0.5 - 5 mm/s (0.02 - 0.2 in/s) stepped | ||
Positional control | 4 µm (160 µin) | |
Positional resolution | 0.25 µm (0.98 µin) | |
Number of data points (selectable) | 200,000 maximum | |
Horizontal arm axis | ||
Arm construction | Lapped ceramic datum | |
Movement range | 200 mm (7.9 in) | |
Speed of traverse | moving: 0.25 - 15 mm/s (0.01 - 0.6 in/s) stepped | |
measuring: 0.25 - 15 mm/s (0.01 - 0.6 in/s) stepped | ||
contacting: 0.5 - 5 mm/s (0.02 - 0.2 in/s) stepped | ||
Over-center travel | 25 mm (0.98 in) | |
Positional control | +/- 5 µm (200 µin) | |
Positional resolution | 0.25 µm (10 µin) | |
Minimum movement | 0.05 mm (0.002 in) | |
Number of data points (selectable) | 200,000 maximum |