Taylor Hobson - Talyrond 130
Roundness Analysis Equipment
Taylor Hobson - Talyrond 130

Benchtop Roundness Analyzer

Taylor Hobson - Talyrond 130

The Talyrond 130 is a software-controlled, air-bearing roundness measuring system with an accuracy of ± 0.02 µm, suitable for most applications.

Technical Description

  • Simple roundness measuring device, suitable for many applications such as measuring roundness, flatness, parallelism, perpendicularity...
  • Needle measuring range up to 2mm; Average resolution up to 30nm
  • Air bearing rotating disc accurate to ± 0.02 μm
  • Ability to quickly determine center and level manually
  • Automatic measurement by motor (Model Talyrond 131)
  • Compact system, simple installation
  • The included μltra Roundness software allows measurement, analysis, and saving of results.
  • Easy to operate and train; High durability, solid construction
  • Integrated electronic interface module

Specifications

Talyrond 130
Measuring CapacityMax diameter200mm(8in)
Max height200mm(8in)
Max weight (balanced load)20kg(44lb)
Weights and DimensionsMain instrument: overall weight38kg(85lb)
Overall length (arm fully retracted)455mm(17.9in)
Overall width285mm(11.2in)
Overall height530mm(20.8in)
Worktable & SpindleWorktable diameter 125mm (4.94in)
Range of manual centering+/- 1.25mm (±0.054in)
Range of manual leveling+/- 30 arc minutes
Height of neutral plane51mm (2in)
Speed of rotation6rpm clockwise nominal
System roundness limit of error**+/- (0.025μm +0.00025μm/mm) +/- (0.98μin+0.25μin/in)
Axial limit of error0.025μm (0.98μin)
Gauge Range & ResolutionMaximum range+/- 1mm (+/- 0.039in)
Resolution at maximum range0.03μm (1.18μin)
Minimum range+/- 0.2mm (+/- 0.008in)
Resolution at min range0.006μm (0.24μin)
Filter OptionsPhase corrected 2CR, gaussian and bandpass filtering available by menu selection.
Filtering is operator selectable from 1-15upr, 1-50upr, 1-150upr, 1-500upr, 15-150upr, 15-500upr and user selected.
Electrical SupplyAlternating supply, single phase with earth (3 wire system)
Voltage90-260v
Frequency47-63Hz
Consumption (total system)250VA max, 160w
Environmental ConditionsTemperature:Operating 10-35°C (50°F - 95°F)
Storage-10 to +50°C (14°F - 122°F)
Temp/time gradientless than 2°C / hour (3.6°F / hour)
Humidity Operating30% to 80% relative, non-condensing
Storage10% to 90% relative, non-condensing
Free air flow rate1.0m / sec maximum steady (39.4in / sec)
Air Source RequirementsMaximum source pressure8.1bar (120psi)
Minimum source pressure5.4bar (80psi)
Air consumption0.037cu.m / min (1.3scfm)
Operating pressure4.1bar (60psi)
Filtering5μm (200μin)
Moisture content - dewpoint2°C (3.6°F)

Related Products

Taylor Hobson - Surtronic R50-R80

Benchtop Roundness Analyzer

Taylor Hobson - Surtronic R50-R80

Taylor Hobson - Surtronic R100 Series

Benchtop Roundness Analyzer

Taylor Hobson - Surtronic R100 Series

Taylor Hobson - Talyrond 131c

Benchtop Roundness Analyzer

Taylor Hobson - Talyrond 131c

Are you interested in our products?
Need a quote for a product or equipment?