X-ray tube with voltage range 10-160kV
Emission tube:
ERESCO MF4 control panel
| Overview | |
| X-ray lamp type: | 160kV metal-ceramic with Tungsten anode |
| Angle of the baffle: | 20° |
| Thick filter: | 0.8 mm ± 0.1 mm in Be |
| Beam opening angle: | 40° x 60° |
| Emission point dimensions (EN 12 543): | 1.0 mm (~0.5 IEC 336) |
| Operating voltage range of the transmitter: | 10 → 160kV (according to capacity table), 1V step |
| Current intensity in the tube: | 0.5 → 10 mA (3.7 mA /160kV) |
| Current and voltage stability: | ± 1% |
| Continuous power: | 600W |
| Power cycle (Ambient temperature 30° C): | 100% |
| Maximum input power: | 1.0 kVA |
| Weight of transmitter tube: | 26.8 kg (59.1 lbs) |
| Protection level: | Ip65 |