GWUT/ LRUT Ultrasound defect detection device
Eddyfi - Sonyks
Sonyks™ represents a significant advancement in guided wave technology.
Gọi (+84) 828 31 08 99 để được tư vấn.
Technical Description
- Advanced GWT technology: Sonyks represents a major leap forward in Guided Wave Testing, redefining data quality, versatility, ease of use, and rapid deployment.
- On-site data analysis: Equipped with an integrated screen, allowing for full data viewing and analysis directly on the device, eliminating the need for a laptop.
- Increased inspection productivity: Inspection time at a single destination location can be reduced by 33% , and overall inspection efficiency can be increased by 50% thanks to superior SNR and the ability to capture all data in a single scan.
- Compatible with various toolings: Supports both Piezo and Magneto tooling, compatible with many types of probe rings on the market, allowing you to utilize your existing probes.
- Portable and durable design: Lightweight, easy to carry, high-quality 10.4-inch touchscreen, hot-swap battery, and integrated pump for convenient operation.
Applications
Sonyks are widely used in many conduit inspection situations due to their ability to control long wavelengths from a single test point:
- Pipeline corrosion inspection up to ~200 m from a single measurement point.
- Guided wave inspection on above‑ground and buried pipelines.
- Flange‑to‑flange pipe inspections.
- Effective for a wide range of pipe diameters (1.5 in to 72 in).
- Long‑range ultrasonic screening (LRUT) applications.
Specifications
| Specification | |
| Dimensions (W × H × D) | 355 × 288 × 127 mm (14.0 × 11.3 × 5.0 in) |
| Weight (with 1 × battery) | 7.2 kg (15.9 lb) |
| Power Requirements | 100–240 VAC. 50–60 Hz |
| Power Supply | Direct VAC or onboard batteries |
| Battery Type | 10.8 V Li‑ion. rechargeable. DOT compliant. Hot‑swappable |
| Battery Typical Life | 6–8 hours |
| Video Output | HDMI |
| Number of Channels Transmit | 40 |
| Transmitter Frequency Range | 5–260 kHz |
| Standard Output Voltage | 200 V peak‑to‑peak |
| Number of Channels Receive | 40 |
| Receiving Gain Range | Up to 100 dB |
| Maximum Sample Range | 365 m: longitudinal pulse‑echo or 200 m: torsional pulse‑echo |
| Maximum Number of Averages | 128 |
| Focusing Options | C‑scan imaging. Time delay focusing |
| Display | 26.4 cm (10.4 in). Non‑reflective (AR coating). Anti‑fingerprint (oleophobic coating). 3 mm strengthened glass. Optically bonded LCD and touchscreen. Passive backlight enhancement |
| Software Options | Sonyks GO (Instrument). Sonyks PRO (Optional Laptop Control) |
| Laptop Connectivity | Optional connection through Wi‑Fi or Gigabit Ethernet |
| Storage | 200 GB SSD |
| Cooling | Sealed and internal fan |
| Onboard Pump | 60 PSI maximum pressure |
| Onboard Collar Pressure Monitoring | Yes |
| GPS | Accurate positioning to 2.5 m (8.2 ft) |
| Instrument Transduction Compatibility | Magnetostrictive. Piezo transducer compatibility |
| Supported Rings | Sonyks Piezo and Magneto tools. Teletest and other commercial PZT rings |
| Piezo Tooling – Transduction Method | Piezoelectric transducers (PZT) |
| Piezo Tooling – Frequency Range | 20–80 kHz broadband collection |
| Piezo Tooling – Pipe Size Range | 15.2–91.4 cm (6–36 in) single collar. 66–182.9 cm (26–72 in) dual collar |
| Piezo Tooling – Sensors | Automatic collar recognition. pipe size. orientation. angular position |
| Piezo Tooling – Max Surface Temperature | 120˚C (248˚F) |
| Magneto Tooling – Transduction Method | Segmented Magnetostrictive Sensors (SMS) |
| Magneto Tooling – Frequency Range | 32 kHz – Test range 22–42 kHz. 64 kHz – Test range 54–74 kHz. 128 kHz – Test range 118–138 kHz |
| Magneto Tooling – Pipe Size Range | 3.8. 5.1. 7.6 and 10.2 cm (1.5. 2. 3. and 4 in) |
| Magneto Tooling – Max Surface Temperature | 80˚C (176˚F). 120˚C (248˚F) short term |
| Teletest Tooling – Transduction Method | Piezoelectric transducer |
| Teletest Tooling – Pipe Size | 15.2–61 cm (6–24 in) single collar. 66–132.1 cm (26–52 in) dual collar. 137.2–198.1 cm (54–78 in) treble collar |
| Teletest Tooling – Frequency Range | 20–80 kHz depending on spacing and wave mode |
| Teletest Tooling – Max Surface Temperature | Standard 120˚C (248˚F). High Temperature (HT) 240˚C (464˚F) |
| Wavemode Compatibility | Multimode 3 ring torsional – 30 mm (1.2 in). 3 ring torsional – 45 mm (1.8 in) |