Electric motor analysis and diagnostic equipment
ATPro - ALL-TEST PRO On-Line III™
ATPOL III™ Electrical Signature Analysis (ESA) with current/voltage signal analysis capabilities
Gọi (+84) 828 31 08 99 để được tư vấn.
Technical Description
- Voltage: 1-600 Vrms in steady mode (higher for special applications); Accuracy 0.1%
- Current: 0.01 – 5000A, AC or DC depending on the included current transformer; Accuracy 0.1% + current transformer accuracy
- Display on LCD screen
- Computer communication and data transfer via Bluetooth
- Highest safety standard in the industry: 600V CAT IV
- Power supply: 12VDC @ 500mA rechargeable battery
Applications
- Check, analyze, and diagnose motor status online using the ESA (Electrical Signature Analysis) method
- Evaluate the entire motor system including engine, bearings, gearbox, belt, drive shaft, power quality, efficiency...
- Detect faults in electrical parts such as stator/rotor coils, cables, control panels, etc.
- Detect mechanical errors (misalignment, loss of concentricity, breakage, dry oil…) in gearboxes, bearings, drive belts, air gaps…
- Analyze power quality such as power factor, voltage deviation, voltage imbalance, connectors…
- Fast data acquisition right at the motor control cabinet. Simple and safe operation.
- Transmit data to computer for management, storage and as a basis for comparison and evaluation of motor status.
- Provide accurate predictions, suggestions, and warnings about motor status.
- Generate detailed reports on motor parameters, status, bearing status, gearbox, power quality, etc.
- Schedule routine maintenance and repairs based on current condition and trend diagnostics of rotating equipment.
- ATPOL III offers unlimited storage with an external memory card slot.
Specifications
General | |||
Measurement | Accuracy and Measurement Range | Display Range | Accuracy |
Voltage | 1-1000 Vrms Steady-State (direct input) | 1-6000 kV (using input ratios) | ±0.1% of reading ±0.3 Vrms |
Frequency | DC, 22-200 Hz, 360 – 440 Hz Fundamental | ±0.25% | |
Current | See included current transformers | 1 mA – 6 Megamps | .1% of reading plus accuracy of |
(using input ratios) | probes | ||
Harmonics | 22-3000 Hz (50th Harmonic @ 50/60 Hz | ±0.25% |